müller coax group

3/2 Way coaxial Direct Acting Valves

MK 10 DR

MK 10 DR
Data Sheets
General Operating Manual
ports threads G 1/4 - G 3/4
function NC / NO
pressure range 0-16 / 0-25 bar
A B max. 25 bar
B A max. 16 bar
A C max. 25 bar
C A max. 25 bar
KV value 2,6 /h
media gaseous  liquid  contaminated 
flow direction see pressure range
switching cycles 200 1/min
switching time opening 40 ms
closing 25 ms
media temperature DC -10 °C — +80 °C
AC -10 °C — +80 °C
ambient temperature DC -10 °C — +80 °C
AC -10 °C — +80 °C
weight 2,2 kg
nominal voltage Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
actuation DC direct-current magnet
AC direct-current magnet with integrated rectifier
insulation rating H 180 °C
protection IP65
energized duty rating ED 100%
connection plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm
M12x1 connector acc. DESINA / VDMA

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Accessories

electrical connection

electrical connection
M12x1 DESINA / VDMA

electrical connection

electrical connection
DIN EN 175301-803

electrical connection

electrical connection
metal terminal box

electrical connection

electrical connection
connector form A DIN EN 175301-803

mounting brackets

mounting brackets

3/2 Way coaxial Direct Acting Valves