müller coax group

High Pressure Lateral Valves

ECD-H 10

ECD-H 10
Data Sheets
General Operating Manual
ports threads G 3/8
function NC / NO
pressure range 0-200 bar
KV value 1,5 /h
media gaseous  liquid 
flow direction A B as marked
switching cycles 100 1/min
switching time opening 250 ms
closing 110 ms
media temperature DC -20 °C — +100 °C
AC -20 °C — +100 °C °C direct mounted pilot valve
ambient temperature DC -20 °C — +60 °C
AC -20 °C — +60 °C °C direct mounted pilot valve
weight 6,0 kg
nominal voltage Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
protection IP65 (P54) DIN 40 050
energized duty rating ED 100%
connection plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Accessories

electrical connection

electrical connection
metal terminal box

electrical connection

electrical connection
connector form A DIN EN 175301-803

limit switch

limit switch
Icomatic
M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C

limit switch

limit switch
Balluff
M12x1, DC 10 - 30 V, -25°C to +70°C