müller coax group

Special Valves

LVP 06

Data Sheets
General Operating Manual
ports threads G 1/4
function NC / NO
pressure range 0-500 bar
KV value 7 l/min
media gaseous
flow direction A B as marked
switching cycles 300 1/min
switching time 100-3000 ms opening
100-3000 ms closing
media temperature -20 °C — +80 °C
ambient temperature -20 °C — +80 °C
weight 2,2 kg

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Product description

This type is a pneumatically actuated valve with 2 port connections and 2 switching positions with a nominal width of 6 mm. Control is either carried out via a direct mounted 3/2 or 5/2 pilot valve or one provided by the customer.

The LVP 06 has been specially designed for high-pressure gases, but can also be used for clean fluids. The valve can be used up to a pressure of 500 bar. This series is used highly successfully in gas filling technology as well as process technology in petrochemicals. The housing material is made of brass, the valve seat is made of Monel. In the home position, the valve can be operated open and closed. The end position can be indicated by means of an inductive limit switch.

Features

  • pressure range up to 500 bar
  • also suitable for oxygen up to 40 bar
  • valve seat made of Monel (suitable for oxygen)
  • fail position NC or NO
  • inductive limit switch for end position monitoring “open” or “closed”
  • for clean gases or fluids
  • compact design
  • control with 3/2 or 5/2 pilot on request

Accessories

limit switch

limit switch
Icomatic
M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C

limit switch

limit switch
Balluff
M12x1, DC 10 - 30 V, -25°C to +70°C

Special Valves