2/2 Way coaxial Externally Controlled Valves
FCF 80

FCF 80

Characteristics

ports flanges PN 16/40
function NC
pressure range 0-16 / 0-40 bar
KV value 133,0 /h
media emulsions  oils  neutral gases 
flow direction A B as marked
switching cycles 50 1/min
switching time opening 350-3000 ms
closing 350-3000 ms
media temperature 60 °C direct mounted pilot valve
ambient temperature 50 °C direct mounted pilot valve
weight 14,5 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
protection IP65 (P54) DIN 40 050
energized duty rating ED 100%

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Data and Downloads

 Data Sheet FCF 80
 General Operating Manual for Valves
 Declaration of Conformity non-electrical Equipment Cat. 2
 Drawing FCF 80

2/2 Way coaxial Externally Controlled Valves

CFM 08
MCF 08
VMK 10
VMK / VFK 15
VMK / VFK 20
VMK / VFK 25
VMK / VFK 32
VMK / VFK 40
VMK / VFK 50
VSV-M / VSV-F 40
VSV-M / VSV-F 50
VSV-F 65
VSV-F 80
VSV-F 100
VSV-F 125
VSV-F 150
VSV-F 200
VSV-F 250
FCF 65
FCF-K 65
FCF 80
FCF-K 80
FCF 100
FCF-K 100
FCF 125
FCF-K 125

Accessories

pilot valve pilot valve
NAMUR (flange port)
5/2-way-pilot, electro-pneumatic, G 1/8, with throttles, p = 4 - 10 bar
pilot valve pilot valve
ISO 1
5/2-way-pilot, electro-pneumatic, G 1/4, p = 4 - 10 bar
pilot valve pilot valve
co-ax (G 1/4")
5/2-way-pilot, electro-pneumatic, G 1/4, p = 4 - 10 bar
electrical connection electrical connection
coil with connector M12x1 DESINA / VDMA
electrical connection electrical connection
connector form B DIN EN 175301-803
limit switch limit switch
Icomatic
M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C
limit switch limit switch
Balluff
M12x1, DC 10 - 30 V, -25°C to +70°C