Lateral Valves
DRV 12

DRV 12

Characteristics

ports threads G 1/2
function NC
pressure range vacuum max. 98%
A B Δp max. 1 bar
B A Δp max. 1 bar
A C Δp max. 1 bar
C A Δp max. 1 bar
KV value 2,7 /h
media gaseous 
flow direction see pressure range
switching cycles 300 1/min
switching time opening 40 ms
closing 25 ms
media temperature DC -10 °C — +80 °C
AC -10 °C — +80 °C
ambient temperature DC -10 °C — +80 °C
AC -10 °C — +80 °C
weight 1,0 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
actuation DC direct-current magnet
AC direct-current magnet with integrated rectifier
insulation rating H 180 °C
protection IP65
energized duty rating ED 100%
connection plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Data and Downloads

 Data Sheet DRV 12
 General Operating Manual for Valves
 Drawing DRV 12

Lateral Valves

RSV 12
RSV 20
RSV 25
RSV 32
RSV 40
RSV 50
DRV 12
DRV 20
DRV 25

Accessories

electrical connection electrical connection
connector form A DIN EN 175301-803