| ports | threads G 1/4 - G 3/4 | 
            
                | function | NC / NO | 
            
                | pressure range | 0-40 bar A  B max. 40 bar
 B  A max. 25 bar
 A  C max. 40 bar
 C  A max. 25 bar
 | 
            
                | KV value | 2,2 m³/h | 
            
                | media | gaseous liquid contaminated | 
            
                | flow direction | as marked | 
            
                | switching cycles | 200 1/min | 
            
                | switching time | opening 135 ms closing 20 ms
 | 
            
                | media temperature | DC -30 °C — +120 °C AC -30 °C — +120 °C
 | 
            
                | ambient temperature | DC -30 °C — +120 °C AC -30 °C — +120 °C
 | 
            
                | weight | 4,0 kg | 
            
                | nominal voltage | Un 24 V DC +5% / -10% Un 230 V 40-60 Hz AC +5% / -10%
 | 
            
                | actuation | DC direct-current magnet AC direct-current magnet with integrated rectifier
 | 
            
                | insulation rating | H 180 °C | 
            
                | protection | IP65 | 
            
                | connection | DC terminal box M 16 x 1.5 AC terminal box, 3 m flying leads
 | 
            
            The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.