Certificated Valves
KB 15 Ex

KB 15 Ex

Characteristics

ports threads G 3/8
function NC
pressure range
bar1010163050100
DN865432
KV value
l/min24,017,413,511,04,11,7
DN865432
media gaseous  liquid 
flow direction A B as marked
switching cycles 210 1/min
switching time opening 100 ms
closing 175 ms
media temperature DC -20 °C — +40 °C
AC -20 °C — +40 °C
ambient temperature DC -20 °C — +40 °C
AC -20 °C — +40 °C
weight 2,8 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
actuation DC direct-current magnet
AC direct-current magnet with integrated rectifier
insulation rating H 180 °C
protection IP65
energized duty rating ED 100%
connection M 16 x 1,5 terminal box

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.