0-200 bar A B max. 200 bar B A max. 100 bar A C max. 200 bar C A max. 200 bar
KV value
7,6 m³/h
media
gaseous liquid highly viscous
flow direction
as marked
switching cycles
200 1/min
switching time
opening 50-3000 ms closing 50-3000 ms
media temperature
60 °C direct mounted pilot valve
ambient temperature
50 °C direct mounted pilot valve
weight
VMK-H 7,8 kg VFK-H 9,2 kg
nominal voltage
Un 24 V DC
Un 230 V 40-60 Hz AC
protection
IP65 (P54) DIN 40 050
energized duty rating
ED 100%
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
Accessories
pilot valve NAMUR (flange port) 5/2-way-pilot, electro-pneumatic, G 1/8, with throttles, p = 4 - 10 bar
pilot valve ISO 1 5/2-way-pilot, electro-pneumatic, G 1/4, p = 4 - 10 bar
electrical connection coil with connector M12x1 DESINA / VDMA
electrical connection connector form B DIN EN 175301-803
limit switch Icomatic M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C
limit switch Balluff M12x1, DC 10 - 30 V, -25°C to +70°C