ports |
threads G 3/8 - G 3/4 flanges PN 16/40/100 |
function |
NC / NO |
pressure range |
0-16 / 0-40 / 0-63 / 0-100 bar |
KV value |
6,0 m³/h (0-16 bar) 2,5 m³/h (0-40 / 0-63 / 0-100 bar) |
media |
gaseous liquid highly viscous gelatinous contaminated |
flow direction |
A B as marked |
switching cycles |
200 1/min |
switching time |
opening 80 ms closing 80 ms |
media temperature |
DC -40 °C — +40 °C
AC -40 °C — +40 °C |
ambient temperature |
DC -40 °C — +40 °C
AC -40 °C — +40 °C |
weight |
MK 3,8 kg FK 5,0 kg |
nominal voltage |
Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
|
actuation |
DC direct-current magnet AC direct-current magnet with separate rectifier outside of the explosion-proof area |
insulation rating |
H 180 °C |
protection |
IP65 |
energized duty rating |
ED 100% |
connection |
M 16 x 1,5 terminal box |
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.