2/2 Way coaxial Externally Controlled Valves

VSV-F 250

ports flanges PN 16
function NC / NO
pressure range 0-16 bar
KV value 650,0 /h
media gaseous liquid highly viscous gelatinous pasty contaminated 
flow direction A B as marked
switching cycles 4 1/min
switching time opening 1500-3000 ms
closing 1500-3000 ms
media temperature 60 °C direct mounted pilot valve
ambient temperature 50 °C direct mounted pilot valve
weight 215,0 kg
nominal voltage Un 24 V DC
Un 230 V 40-60 Hz AC
protection IP65 (P54) DIN 40 050
energized duty rating ED 100%

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Accessories

pilot valve

pilot valve
co-ax (threaded ports)
5/2-way-pilot, electro-pneumatic, G 1/8, p = 4 - 10 bar

electrical connection

electrical connection
coil with connector M12x1 DESINA / VDMA

electrical connection

electrical connection
connector form B DIN EN 175301-803

limit switch

limit switch
Icomatic
M12x1, DC 10 - 60 V, AC 15 - 250 V, -25°C to +85°C

limit switch

limit switch
Balluff
M12x1, DC 10 - 30 V, -25°C to +70°C

limit switch

limit switch
Honeywell
change-over

2/2 Way coaxial Externally Controlled Valves